*Discount automatically applied. T&Cs apply
*Discount automatically applied. T&Cs apply
*Discount automatically applied. T&Cs apply
*Discount automatically applied. T&Cs apply
*Discount automatically applied. T&Cs apply
*Discount automatically applied. T&Cs apply
CPAP Boussignac Respiratory Assistance Kit
OV5562.303
Regular priceCPAP Boussignac single use kit is a respiratory assistance device for patients with spontaneous ventilation allowing maintenance in the airways of a pressure greater than atmospheric pressure during the entire respiratory cycle.
CPAP Boussignac adolescent single use kit is a respiratory assistance device for patients with spontaneous ventilation allowing maintenance in the airways of a pressure greater than atmospheric pressure during the entire respiratory cycle.
The CPAP mode of ventilation allows:
- To recruit collapsed alveoles
- To restore a satisfactory level of functional residual capacity
- To improve gas exchange at the level of the alveolocapillary membrane
- to decrease pulmonary resistance
- To decrease the work of breathing
- To redistribute the alveolar liquid to the interstitial space in case of acute pulmonary oedema
The Boussignac CPAP and its manometer connector is a device for connection to a face mask with its 22 mm male connector, the crenellated upper part remaining open to the air.
This device comprises 2 lateral ports:
- The upper port is preconnected to a an extension tube (length 200 cm) for connection to an air or oxygen source
- The bottom port (colourless translucent) allows:
. controlling pressure (use manometer code 527.01),
. an additional oxygen supply if the gas administered to the patient via the upper port is air,
. CO2 monitoring.
How it works:
The gases administered to the patient (air, air-oxygen mixture or pure oxygen) pass through the extension tube and arrive in a circular chamber where the gases can only escape into the central zone passing through 4 micro-channels. At that moment, the injection speed of the gases is greatly increased. Deflector at the exit site of the micro-channels eject the gases arriving at high speed towards the opposite wall.
The collision of gas molecules between themselves generates a turbulence which creates a virtual valve and simultaneously the speed of gases is transformed in pressure. This pressure depends directly on the flowrate: if the flowrate (the amount of gas injected) is increased, the pressure will increase; if the flowrate is decreased, the pressure will decrease.
N.B. It is possible to connect the Boussignac CPAP to an endotracheal tube or to a tracheostomy tube using the adaptor code 555.01 together with an artificial nose such as Hygroflux code 501.01.
*Codes 5562.300/400/500/600: Odorless mask.
*Codes 5562.303/403/503/603: Vanilla scented mask.
The CPAP Boussignac set includes:
- 1 CPAP Boussignac with a 200 cm long green extension tube and with a 50 cm long extension tube to connect the Boussignac CPAP to a manometer.
-1 face mask (available in 4 sizes) :
. one ÒadolescentÓ mask code 5562.300/303*
. one Òadult-small sizeÓ mask code 5562.400/403*
. one Òadult-medium sizeÓ mask code 5562.500/503*
. one Òadult-large sizeÓ mask code 5562.600/603*
- 1 fixation harness code. 5559.01
UOI Units: Box
UOI: 1
Contains Latex: No
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device:ÊNo
CPAP Boussignac Kit with Nebuliser
OV5572403
Regular priceCPAP Boussignac single use adult respiratory assistance kit with nebuliser
Respiratory assistance device for patients with spontaneous ventilation allowing maintenance in the airways of a pressure greater than atmospheric pressure during the entire respiratory cycle.
The CPAP mode of ventilation allows:
- to recruit collapsed alveoles
- to restore a satisfactory level of functional residual capacity
- to improve gas exchange at the level of the alveolocapillary membrane
-to decrease pulmonary resistance
- to decrease the work of breathing
- to redistribute the alveolar liquid to the interstitial space in case of acute pulmonary oedema
The Boussignac CPAP and its manometer connector is a device for connection to a face mask with its 22 mm male connector, the crenellated upper part remaining open to the air.
This device comprises 2 lateral ports:
- the upper port is preconnected to a an extension tube (length 200 cm) for connection to an air or oxygen source
- the bottom port (colourless translucent) allows:. controlling pressure (use manometer code 527.01). an additional oxygen supply if the gas administered to the patient via the upper port is air. CO2 monitoring
How it works:
The gases administered to the patient (air, air-oxygen mixture or pure oxygen) pass through the extension tube and arrive in a circular chamber where the gases can only escape into the central zone passing through 4 micro-channels. At that moment, the injection speed of the gases is greatly increased. Deflector at the exit site of the micro-channels eject the gases arriving at high speed towards the opposite wall.
The collision of gas molecules between themselves generates a turbulence which creates a virtual valve and simultaneously the speed of gases is transformed in pressure. This pressure depends directly on the flowrate: if the flowrate (the amount of gas injected) is increased, the pressure will increase; if the flowrate is decreased, the pressure will decrease.
*Codes 5572.300/400/500/600: Odorless mask.
*Codes 5572.303/403/503/603: Vanilla scented mask.
UOI Units: Each
UOI: 1
Contains Latex: No
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device: No
Thoracic Trocar and Drain
OV626.16
Regular priceThoracic trocar and drain for thoracic / pleural drainage (pneumothorax, hemothorax, chylothorax, pyothorax)
This device is made of:
Available in the following sizes:
Fr 12 – 16: Length 25 cm
Fr 20 – 24 – 28 – 32: Length 40 cm
Thoracic Chest Drainage Valve - Pack of 25
OV0669.10
Regular priceThoracic Chest Drainage Valve - Pack of 25
Non-return valve for thoracic drainage (Heimlich type).
Valve body in flexible and transparent polyurethane with natural rubber sleeve in “duck’s bill” shape acting as a non-return valve. This device is connected directly onto the patient’s pleural or thoracic drain (adult, paediatric), or indirectly, using connector code 800.01 and an extension tube for neonates and infants.
This product allows thoracic drainage to continue without risk to the patient even when transported, as the non-return valve means that the drain does not have to be clamped.
Tube, Trachea Without cuff 8 mm
OV85089
Regular priceTube, Trachea Without cuff 4 mm
OV88589
Regular priceThoracic Trocar Drain - Pack of 10
OV0636.14
Regular price28fr x 50cm Thoracic Drain
Transparent PVC drain with radiopaque line. Markings every 2cm from 2 to 24cm after the eyes.
Non-traumatic proximal end which can be connected to a Heimlich valve or to collecting / suction system after shortening.
Drain available in French size 16 Fr, 20 Fr, 24 Fr, 28 Fr and 32 Fr.
UOI Units: Box
UOI: 10
Contains Latex: No
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device: Yes
Thoracic Drain - Pack of 10
OV0653.28
Regular price28fr x 50cm Thoracic Drain
Transparent PVC drain with radiopaque line. Markings every 2cm from 2 to 24cm after the eyes.
Non-traumatic proximal end which can be connected to a Heimlich valve or to collecting / suction system after shortening.
Drain available in French size 16 Fr, 20 Fr, 24 Fr, 28 Fr and 32 Fr.
UOI Units: Box
UOI: 10
Contains Latex: No
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device: Yes
Thoracic Chest Drainage Kit
OV0639.14
Regular priceContents:
- 1 XRO trocar drain
- 1 60x50cm fenestrated drape
- 2 rectangular cups for detergent and disinfecting agents
- 4 pads
- 8 10x10cm gauze dressings
- 2 dressing forceps
2 10ml syringes
- 1 38_1.2mm (18G) needle for drug aspiration
- 1 15_0.5mm (25G) needle for skinwheal
- 1 38_0.8mm (21G) needle for local anaesthesia
- 1 90_1.2mm (18G) needle for exploratory puncture (38mmx0.9mm (20G) for codes 639.08 and 639.14)
- 2 suture needles
- 1 scalpel
- 1 dual suction valve
- 1 plastic bag with connector for collecting the drained liquid
- 1 coil of adhesive bandage, 75mm wide
- 1 pair of gloves.
Code 639.08 Paediatric Trocar drain code 625.08.
Code 639.14 Paediatric Trocar drain code 636.14
Code 639.18 Trocar drain code 636.18
Code 639.24 Trocar drain code 636.24
Code 639.28 Trocar drain code 636.28
UOI Units: Each
UOI 1
Contains Latex: Yes
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device: Yes
PVC Suction Catheter - Pack of 50
OV533.12
Regular price12Fr x 35cm PVC suction catheter for tracheal and bronchial aspiration.
PVC suction catheter for tracheal and bronchial aspiration. Open, straight and rounded tip, x-ray opaque
PVC suction catheter for tracheal and bronchial aspiration. Open, straight and rounded tip.
The mark at 16 cm from the distal tip for sizes 4 Fr to 8 Fr shows when the suction catheter has reached the bevelled tip of endotracheal tube code 516, 520, 5516 and 5520.20/25/30/35.
Code 533.xx: Proximal end with small connector for suction catheters from 4 Fr to 10 Fr and large connector for suction catheters from 12 Fr to 18 Fr. Code 530.xx has no colour-coding.
Code 70533.xx: The proximal end of all sizes consists of a large connector with colour-code.
4 Fr, 5 Fr and 6 Fr : Length 27 cm
7 Fr, 8 Fr, 9 Fr, 10 Fr, 12 Fr, 14 Fr, 16 Fr, 18 Fr and 21 Fr : Length 33 cm
UOI Units: Box
UOI: 50
Contains Latex: No
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device: Yes
Pleural Drain - Pack of 10
OV0635.12
Regular price12Fr x 15cm pleural drain device for thoracic and pleural drainage (pneumothorax, hemothorax, chylothorax, pyothoraxÉ)
made of a metallic trocar and a drain (PVC -XRO) with 2 lateral eyes. Fixation collar. Markings at 5 and 10 cm from the distal tip.
Fr 12 -14 -18.
UOI Units: Box
UOI: 10
Contains Latex: No
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device: Yes
Paediatric Catheter - Pack of 50
OV0420.04
Regular priceVesical non lubricated paediatric catheter
Catheter vesical straight Nelaton type PVC XRO
UOI Units: Box
UOI: 50
Contains Latex: No
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device: Yes
Open Suction Catheter - Pack of 20
OV0802.00
Regular priceOpen Suction Catheter Accessory Control Lateral Eye
UOI Units: Each
UOI: 1
Contains Latex: No
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device: Yes
Mucus Extractor
OV0534.20
Regular price8Fr x 40cm disposable valve catheter
Catheter vesical straight nelaton type pvc xro 40cm long 8Fr
Sample collection device for aspiration of mucus congesting the upper airways of the newborn or for suctioning tracheal / bronchial secretions (of newborns, children and adults) which will be analysed in laboratory.
The mucus extractors include:
1 container (capacity 25 ml), with graduations from 0 to 25 ml for all models except code 534.20 (capacity 70 ml) with graduations from 0 to 70 ml.
1 tracheal suction tube
Note 1: The paediatric mucus extractors code 534.10 and 534.101 are supplied with 2 suction catheters: a 10 Fr suction catheter connected to the container and an additional 6 Fr catheter to replace the 10 Fr one if suction is carried out on a low-weight baby.
Note 2: The mucus extractor code 534.91 is supplied without suction catheter. Instead of the suction catheter, this mucus extractor is fitted with a conical connector (on a 11 cm long tubing) which allows the user to adapt suction catheters of different sizes.
1 PVC extension tube with small or large funnel (see technical features p. 3) to connect the mucus extractor to the suction source.
1 separate lid for safe sealing and transport of the aspirate
1 label
UOI Units: Box
UOI: 15
Contains Latex: No
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device: Yes
Disposable Valve Catheter - Pack of 50
OV0420.08
Regular priceCatheter vesical straight Nelaton type PVC XRO
UOI Units: Box
UOI: 50
Contains Latex: No
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device: Yes
CPAP Boussignac Valve and Tubing - Pack of 5
OV557013
Regular price
Respiratory assistance device for patients with spontaneous ventilation allowing maintenance in the airways of a pressure greater than atmospheric pressure during the entire respiratory cycle.
The CPAP mode of ventilation allows:
- to recruit collapsed alveoles
- to restore a satisfactory level of functional residual capacity
- to improve gas exchange at the level of the alveolocapillary membrane
- to decrease pulmonary resistance
- to redistribute the alveolar liquid to the interstitial space in case of acute pulmonary oedema.
The Boussignac CPAP and its manometer connector is a device for connection to a face mask with its 22 mm male connector, the crenellated upper part remaining open to the air.
This device comprises 2 lateral ports:
- the upper port is preconnected to an extension tube (length 200 cm) for connection to an air or oxygen source
- the bottom port (colourless translucent) allows:. controlling pressure (use manometer code 527.01),
- an additional oxygen supply if the gas administered to the patient via the upper port is air,. CO2 monitoring
How it works:
The gases administered to the patient (air, air-oxygen mixture or pure oxygen) pass through the extension tube and arrive in a circular chamber where the gases can only escape into the central zone passing through 4 micro-channels. At that moment, the injection speed of the gases is greatly increased. Deflectors at the exit site of the micro-channels eject the gases arriving at high speed towards the opposite wall.
The collision of gas molecules between themselves generates a turbulence which creates a virtual valve and simultaneously the speed of gases is transformed in pressure. This pressure depends directly on the flowrate: if the flowrate (the amount of gas injected) is increased, the pressure will increase; if the flowrate is decreased, the pressure will decrease.
N.B. It is possible to connect the Boussignac CPAP to an endotracheal tube or to a tracheostomy tube using the adaptor code 555.01 together with an artificial nose such as Hygroflux code 501.01.
UOI Units: Box
UOI: 5
Contains Latex: No
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device: Yes
CPAP Boussignac Nebuliser Accessories Kit - Pack of 10
OV556901
Regular priceProduct Summary
CPAP Boussignac universal size, anti-tilt nebuliser accessories kit
Support products for single use CPAP unit
UOI Units:Box
UOI: 10
CPAP Boussignac Manometer
OV0527.01
Regular priceCPAP peep manometer pressure gauge
Manometer to measure the pressure generated by the CPAP Boussignac in the patients airways.
The connecting tube is supplied in the packaging containing the VYGON-BOUSSIGNAC CPAP code 5570.13.
The manometer must be connected to the colourless translucent port on the CPAP device. It indicates each centimetre of H2O from 0 to 25cm.
The manometer is encased in a protective polyurethane housing and is supplied with a manometer attachment cord (code 7.254.15.03).
UOI Units: Each
UOI: 1
Contains Latex: No
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device: No
CPAP Boussignac Flowmeter
OV5563.31
Regular priceFlowmeter measuring the flow of air up to 30l/min, while the flowmeters available in the hospital generally only measure flow rates of air up to 15l/min
UOI Units: Each
UOI: 1
Contains Latex: No
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device: No
CPAP Boussignac Fixation Harness - Pack of 5
OV5559.01
Regular priceThe fixation harness holds a face mask on the patients face and reduces the risk of leakage.
The fixation harness holds a face mask on the patients face and reduces the risk of leakage.
Suitable face masks size 3, 4, 5 and 6.
Material: silicone
UOI Units: Box
UOI:Ê5
Contains Latex: No
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device: No
CPAP Boussignac FiO2 regulator device - Pack of 5
OV556601
Regular priceCPAP Boussignac accessories kit FIO2 oxygen regulator device
CPAP Boussignac FIO2 oxygen regulator device accessories kit
Support products for single use CPAP unit
Device which fits in between the facial mask and the Boussignac CPAP.
Through a leak generated by the device, the FiO2 can be modified.
The FiO2 regulator device comes with an angle to avoid the patient receiving a direct flow of oxygen in the eyes.
This product allows to change the FiO2 in emergency conditions when air is not available (pre-hospital care). Indeed, this product is perfectly adapted to COPD patients requiring ventilation assistance.
Possible values are 30%, 50% and 100%.
Fi02 regulator device used to regulate the amount of oxygen delivered
UOI Units: Box
UOI: 5
Contains Latex: No
Contains DEHP: No
Pyrogen Free: No
Sterile Medical Device: Yes
Boussignac CPAP+ kit
OVV08776615
Regular priceA CPAP machine and mask to deliver constant and steady air pressure
FreeO2 Automated Oxygen Therapy
Regular priceAutomated oxygen titration and weaning
A new and innovative technology designed to automate oxygen titration and weaning to regulate SP02Êlevels
Regardless of a patientÕs age (infant, child or adult), their oxygen needs and response times, FreeO2Êautomatically adjusts the oxygen flow rate required to maintain target oxygenation set by the clinician, until the patient is fully weaned.
FreeO2Êoperates on a closed loop and continuously adjusts the flow rate administered between 0 and 20 l/min (with or without humidification) based on blood oxygen saturation (SpO2).
Patients are therefore treated according to their needs, which reduces the risks of complications relating to hypoxia and hyperoxia. This means healthcare staff are also able to implement all applicable clinical recommendations without difficulty.
UOI Units:ÊSingle
UOI:Ê1