Portex Thermovent T2 Heat & Moisure Exchanger
OV2395
Regular priceSterile, single use heat and moisture exchanger. Provides effective humidification for spontaneously breathing patients whose upper airways are bypassed by a tracheostomy tube. Device can be used for a maximum period of 24 hours. Now there is a new oxygen accessory line available. The Thermovent T2 Oxygen Line is a specific designated oxygen tube for use with the Portex® Thermovent T2.
Moisture Output
25mg 1-1 H2O @ 15 breath/min-1 Tidal volume 500ml
Resistance to Flow
0.3 hPa (cmH2O) at gas flow rate 0.5l/sec-1 (30l/min) [0.6cm H2O 1-1 sec-1]
0.7 hPa (cmH2O) at gas flow rate 1.0l/sec-1 (60l/min) [0.7cm H2O 1-1 sec-1]
1.2 hPa (cmH2O) at gas flow rate 1.5l/sec-1 (90l/min) [0.9cm H2O 1-1 sec-1]
Dead Space
11ml
weight 7.5g
Inspired Oxygen Concentration (%)
15 breath/min
Tidal volume 500ml
O2 l/min: 1 2 3 4 5 6 7 8 9 10
O2%: 27 33 37 42 45 47 53 54 57 60
Portex Thermovent T2 Heat & Moisure Exchanger
OV2395
Regular priceSterile, single use heat and moisture exchanger. Provides effective humidification for spontaneously breathing patients whose upper airways are bypassed by a tracheostomy tube. Device can be used for a maximum period of 24 hours. Now there is a new oxygen accessory line available. The Thermovent T2 Oxygen Line is a specific designated oxygen tube for use with the Portex_¨ Thermovent T2.
Moisture Output
25mg 1-1 H2O @ 15 breath/min-1 Tidal volume 500ml
Resistance to Flow
0.3 hPa (cmH2O) at gas flow rate 0.5l/sec-1 (30l/min) [0.6cm H2O 1-1 sec-1]
0.7 hPa (cmH2O) at gas flow rate 1.0l/sec-1 (60l/min) [0.7cm H2O 1-1 sec-1]
1.2 hPa (cmH2O) at gas flow rate 1.5l/sec-1 (90l/min) [0.9cm H2O 1-1 sec-1]
Dead Space
11ml
weight 7.5g
Inspired Oxygen Concentration (%)
15 breath/min
Tidal volume 500ml
O2 l/min: 1 2 3 4 5 6 7 8 9 10
O2%: 27 33 37 42 45 47 53 54 57 60
Thermovent¨ T2, Heat Moisture Exchanger (HME) with sampling / suction port, integral oxygen inlet connector, Adult 15Fr connection - Pack of 25
OV2394
Regular priceThermovent¨ T2, Heat Moisture Exchanger (HME) with sampling / suction port, integral oxygen inlet connector, Adult 15Fr connection
Sterile, single use heat and moisture exchanger. Provides effective humidification for spontaneously breathing patients whose upper airways are bypassed by a tracheostomy tube. Device can be used for a maximum period of 24 hours. Now there is a new oxygen accessory line available. The Thermovent T2 Oxygen Line is a specific designated oxygen tube for use with the Portex¨ Thermovent T2.
1000cc Jar for Boscarol Suction Units (for use with liner, with adaptor & connector)
OVASP001
Regular priceOB2012 Emergency Suction Unit with Autoclavable Jar, Wall Bracket, Mains & 12v Chargers
OVA000239000
Regular priceOB 2012 Portable Suction Unit has a silent, powerful operation with an air flow > 30lt. (High Vacuum High Flow). The OB 2012 is designed with a adjustable suction with analogue gauge 0 to >800 mbar (80 kPa) as well as choice of collection jars, disposable or autoclaveable. The OB 2012 portable suction unit is operable and rechargeable through any 12 VDC vehicle source or any 220 VAC with suitable battery charger. Optional wall bracket available, with integrated cable for an external 12V source.
Emergency Portable Suction Unit with Disposable Liner (ASP001)
OV602
Regular price1000cc Jar for OB2012 Suction Units (Autoclavable & for use with Liner)
OV606
Regular price
Thermovent® T2, Heat Moisture Exchanger (HME) with sampling / suction port, integral oxygen inlet connector, Adult 15Fr connection - Pack of 50
OV100/570/022
Regular priceThermovent® T2, Heat Moisture Exchanger (HME) with sampling / suction port, integral oxygen inlet connector, Adult 15Fr connection - Pack of 50
Sterile, single use heat and moisture exchanger. Provides effective humidification for spontaneously breathing patients whose upper airways are bypassed by a tracheostomy tube. Device can be used for a maximum period of 24 hours. Now there is a new oxygen accessory line available. The Thermovent T2 Oxygen Line is a specific designated oxygen tube for use with the Portex¨ Thermovent T2.